1. Registration trouble? Please use the "Contact Us" link at the bottom right corner of the page and your issue will be resolved.
    Dismiss Notice

generator not charging

Discussion in 'Early CJ5 and CJ6 Tech' started by farwest, Nov 1, 2013.

  1. Nov 1, 2013
    farwest

    farwest New Member

    Joined:
    Nov 30, 2008
    Messages:
    13
    My jeep is a 1965 cj5 with a 4cyl. I hadn't run it in 6 months and after starting the engine all was working as it should. 3 days later upon starting the red gen light would not go out. I checked the battery and it was not being charged. In the past the red gen light would come on if the engine idle became too low. The jeep is original with the generator, no alternator. I'm thinking the regulator is not working, is there a good way to test both the regulator and generator separately in the vehicle?
    Thanks
     
  2. Nov 2, 2013
    Twin2

    Twin2 not him 2024 Sponsor 2023 Sponsor 2022 Sponsor

    Virginia Beach, VA
    Joined:
    Apr 28, 2011
    Messages:
    5,421
    yes you can , unhook field wire at voltage regulator . take a jumper wire and go from battery 12V to field terminal on generator . and start engine , with voltage gauge . you should have 12 to 14 volts with engine running faster than idle speed . if not generator is bad , if you do have voltage regulator is bad . been a long time since I had a generator . If I remember right . if you replace generator , you will have to momentary jump battery terminal and field terminal at voltage regulator to polarize generator [​IMG]
     
    Last edited: Nov 2, 2013
  3. Nov 2, 2013
    PeteL

    PeteL If it wasn't for physics, and law enforcement... 2024 Sponsor 2023 Sponsor 2022 Sponsor

    Hills of NH
    Joined:
    Aug 3, 2003
    Messages:
    9,823
    May be as simple as worn brushes in the generator, or a loose connector or broken wire. Fan-belt tight enough?

    Twin@ is correct about polarizing - doesn't hurt to do it, just to be sure.
     
  4. Nov 2, 2013
    Howard Eisenhauer

    Howard Eisenhauer Administrator Staff Member

    Tantallon, Nova...
    Joined:
    Nov 22, 2003
    Messages:
    8,124
  5. Nov 5, 2013
    jeepermc

    jeepermc Active Member

    Western WA
    Joined:
    May 25, 2011
    Messages:
    1,192
    The one in my 6 sometimes stays on too.... I just tap the end of the generator with a hammer until it goes out and starts charging again. I need to pull it. I think one of the brushes sticks from sitting in a field so long.
     
New Posts