1. Registration trouble? Please use the "Contact Us" link at the bottom right corner of the page and your issue will be resolved.
    Dismiss Notice

70 cj5 v6 no spark

Discussion in 'Early CJ5 and CJ6 Tech' started by koopa00, Sep 7, 2014.

  1. Sep 7, 2014
    koopa00

    koopa00 New Member

    Joined:
    May 18, 2014
    Messages:
    13
    Po had even fire hei, I got a prestolite for it put new points in. Hooked it up and then after some melted wire figured out ballast resistor was gone. Picked up a new one had lil over 6volts. Later on tested again then had 12volts . Got another resistor and condenser again 12volts and yet to see a spark. any ideas?
     
  2. Sep 7, 2014
    PeteL

    PeteL If it wasn't for physics, and law enforcement... 2024 Sponsor 2023 Sponsor 2022 Sponsor

    Hills of NH
    Joined:
    Aug 3, 2003
    Messages:
    9,860
    Checked your coil?
     
  3. Sep 7, 2014
    Walt Couch

    Walt Couch sidehill Cordele, Ga. 2024 Sponsor 2023 Sponsor 2022 Sponsor

    cordele, Ga.
    Joined:
    Mar 29, 2007
    Messages:
    5,925
    Your not telling us where you are reading the voltages from. Key (on) input to ballast resistor or key (on) after the ballast resistor or key (on) + terminal of coil or key (on) - terminal of coil or?
     
  4. Sep 7, 2014
    koopa00

    koopa00 New Member

    Joined:
    May 18, 2014
    Messages:
    13
    Ive got the voltage from b4 and after resistor. At the coil and to the distrubtor all now read 12volts
     
  5. Sep 7, 2014
    Walt Couch

    Walt Couch sidehill Cordele, Ga. 2024 Sponsor 2023 Sponsor 2022 Sponsor

    cordele, Ga.
    Joined:
    Mar 29, 2007
    Messages:
    5,925
    Your 12V at the coil going to the distributor should trigger low-hi when cranking. If that is not happening then make sure your bypass wire from the "R" terminal on the starter solenoid is connected to the circuit feeding the coil +. If you are still getting a steady 12V at the - terminal of the coil when cranking then your points are no good/are not closing/or the breaker plate ground wire is broken.
     
  6. Sep 7, 2014
    koopa00

    koopa00 New Member

    Joined:
    May 18, 2014
    Messages:
    13
    The wiring has been butchered by another professional electrician . I do not have the 12volts bypass to the coil. I got green wire from firewall to ballast resistor to coil to distrubtor. No voltage regular off alternator. No 12volts from starter
     
  7. Sep 7, 2014
    Walt Couch

    Walt Couch sidehill Cordele, Ga. 2024 Sponsor 2023 Sponsor 2022 Sponsor

    cordele, Ga.
    Joined:
    Mar 29, 2007
    Messages:
    5,925
    Do you have the delco or prestolite starter. A pic would help.
     
  8. Sep 7, 2014
    koopa00

    koopa00 New Member

    Joined:
    May 18, 2014
    Messages:
    13
    Prestolite. How do you upload pictures from phone?
     
  9. Sep 7, 2014
    PeteL

    PeteL If it wasn't for physics, and law enforcement... 2024 Sponsor 2023 Sponsor 2022 Sponsor

    Hills of NH
    Joined:
    Aug 3, 2003
    Messages:
    9,860
    Are your points still gapped correctly - and clean? Can you get a spark from the coil HT wire if you tweak the points manually, with the ignition on?
     
  10. Sep 8, 2014
    koopa00

    koopa00 New Member

    Joined:
    May 18, 2014
    Messages:
    13
    New Points set and been checked and reset. Will test that after work today. Thanks for all the help and replys
     
  11. Sep 8, 2014
    PeteL

    PeteL If it wasn't for physics, and law enforcement... 2024 Sponsor 2023 Sponsor 2022 Sponsor

    Hills of NH
    Joined:
    Aug 3, 2003
    Messages:
    9,860
    I always give them a final polish by pulling a clean business card through the points - has 'fixed' a no-start more than once.
     
  12. Sep 11, 2014
    koopa00

    koopa00 New Member

    Joined:
    May 18, 2014
    Messages:
    13
    Ok im now getting a spark im just outta time . Thanks for all the help cannot wait to drive it with it running right
     